The Master Science Gas Chromatograph EPC is a fully electronic GC with up to 18 channels of pressure and flow control and a 10-inch capacitive touch screen. Pressure is regulated to 0.001 psi with compensation for ambient temperature and pressure.
The column oven of 23 L or more runs from 2 °C above room temperature to 450 °C and heats at 250 °C per minute or faster. Three inlets and up to four detectors can be fitted, and dual independent ovens allow multi-valve, multi-column set-ups for gas analysis.
Technical Specifications
Specifications of the Master Science Gas Chromatograph EPC:
- Brand: Master Science
- Model Number: MSGC-906SWISS
- SKU: MSGC-906SWISS
- Brand: Master Science
- Model Number: MSGC-906SWISS
- SKU: MSGC-906SWISS
- Pressure/Flow Control: Up to 18 EPC channels
- Pressure Control Accuracy: 0.001 psi
- Inlets Supported: 3
- Detectors Supported: Up to 4
- Temperature Control: 8 independent channels
- Display: 10-inch colour capacitive touch screen
- Column Oven Temperature: Room temperature +2 °C to 450 °C
- Minimum Temperature Step: 0.01 °C
- Maximum Heating Rate: ≥250 °C/min
- Cooling Time: 450 °C to 50 °C in <3.2 min
- Temperature Programme: ≥99 steps, 100 plateaus
- Oven Stability: <0.01 °C per ±1 °C ambient change
- Oven Volume: ≥23 L; dual independent ovens
- Inlet Maximum Temperature: 450 °C
- Inlet Pressure Range: 0-50 psi, 0-200 psi
- Maximum Split Ratio: 1:10000
- Flow Setting Range: 0-500 mL/min, 0-1250 mL/min; accuracy 0.01 mL/min
- Carrier Gas Modes: Constant pressure, flow or linear velocity; programmed pressure, flow or linear velocity; pulse injection
- FID: 450 °C; ≤1.1 pg C/s (n-hexadecane); linear range ≥10⁷; auto-ignition
- TCD: Sensitivity ≥12000 mV·mL/mg; noise ≤0.05 mV; linear range ≥10⁵
- FPD: 450 °C; P ≤80 fg/s, S ≤8 pg/s (methyl parathion)
- ECD: ⁶³Ni source; 400 °C; ≤1.0×10⁻¹⁴ g/mL; linear range ≥10⁴
- NPD: 400 °C; N ≤1×10⁻¹² g/s; P ≤5×10⁻¹³ g/s
Key Benefits
- Repeatable retention times: the Master Science Gas Chromatograph EPC controls pressure to 0.001 psi.
- Short cycle times: fast heating and cool-down in under 3.2 minutes.
- Complex gas methods: dual ovens support five valves and seven columns.
- Planned maintenance: usage tracking with septum replacement reminders.
- Broad detector choice: FID, TCD, FPD, ECD and NPD.
A related model is the Master Science gas chromatograph GC analyzer.
Product Features
Control
- 10-inch high-definition capacitive touch screen
- Real-time monitoring of operating status and key components
- User-set replacement thresholds for consumables
Gas Path
- Full electronic pressure control
- Ambient temperature and pressure compensation
- Independent split cold trap and septum purge trap
Oven
- Large oven with fast, uniform heating
- Automatic oven over-temperature protection
- Dual column ovens with independent control
Injection
- Split/splitless capillary, purged packed, cool on-column and PTV inlets
- Valve, headspace and thermal desorption injection
- Software control of liquid autosampler for single and sequence runs
Applications
The Master Science Gas Chromatograph EPC is applied to:
- Natural gas sulfide analysis
- Liquefied petroleum gas analysis
- Rapid refinery gas analysis
- Refinery flue gas analysis
Optional Accessories
- Automatic liquid sampler
- Headspace autosampler
- Hydrogen generator
- Compressed air generator
- FID, TCD, FPD, ECD and NPD detectors
Common Problems and How This GC Helps
How the Master Science Gas Chromatograph EPC improves routine GC work:
- Drifting flows with manual regulators: electronic control with compensation.
- Long waits between runs: rapid oven cooling.
- Leaking septa noticed too late: replacement reminders.
- Multiple instruments for refinery gas: multi-valve, multi-column capability in one unit.