ELISA Microplate Reader with Monochromator, 200-1000 nm, 0-4.0 OD, 96/384-Well Absorbance

Model / SKU MSMPR-A200SWISS,MSMPR-A200HTSWISS

Inhouse product


Share

The ELISA Microplate Reader with Monochromator is a full-wavelength absorbance reader for 96-well and 384-well microplates. A grating monochromator selects any wavelength from 200 to 1000 nm in 1 nm steps, so ELISA, protein and nucleic acid assays can run without changing filters.

A xenon flash lamp and a double-beam design with two silicon photodetectors give a 0-4.0 OD measuring range with linearity of R² ≥ 0.999 from 0 to 3.0 Abs. The ELISA Microplate Reader with Monochromator is offered in two versions: the standard model and the HT model, which adds a cuvette slot for single-sample readings from 200 to 1000 nm with incubation.

Technical Specifications

undefined

  • Brand: Master Science
  • Model Number: MSMPR-A200SWISS,MSMPR-A200HTSWISS
  • SKU: MSMPR-A200SWISS,MSMPR-A200HTSWISS
  • Wavelength Selection: Monochromator
  • Wavelength Range: 200-1000 nm, 1 nm step
  • Light Source: Xenon flash lamp
  • Wavelength Accuracy: 2 nm
  • Wavelength Repeatability: 0.2 nm
  • Bandwidth: < 2.5 nm
  • Optical System: Double beam, 2 silicon photodetectors
  • Plate Types: 96-well and 384-well plates
  • Detection Mode: Absorbance
  • Measuring Range: 0-4.0 OD
  • Linearity: R² ≥ 0.999 (0-3.0 Abs)
  • Absorbance Accuracy: ±(1.0% + 0.003 Abs) at 0-2.0 Abs; ±2.0% at 2.0-2.5 Abs
  • Absorbance Repeatability: CV < 0.5% (accurate mode); CV < 1.0% (fast mode)
  • Read Time (96-well): < 8 s (fast mode); < 28 s (accurate mode)
  • Shaking: Linear, 3 speeds
  • Incubation: RT+4°C to 45°C, ±0.5°C at 37°C
  • Cuvette Slot (HT model): 200-1000 nm, with incubation
  • Display: 10-inch touch screen
  • Storage: 16 GB, more than 20,000 data files
  • Interfaces: 1 × USB-B, 2 × USB-A, 1 × network port
  • Power Supply: DC 24 V, 6.67 A
  • Dimensions: 300 × 500 × 260 mm
  • Net Weight: 15.5 kg
  • Gross Weight: 21 kg
  • Package Size: 690 × 490 × 500 mm

Key Benefits

  • Any Wavelength, No Filters: The monochromator covers 200-1000 nm in 1 nm steps, so new assays need no extra filter purchases.
  • Two Reading Modes: Fast mode reads a 96-well plate in under 8 s; accurate mode reads it in under 28 s with CV below 0.5%.
  • Wide Linear Range: Double-beam optics give R² ≥ 0.999 from 0 to 3.0 Abs and a measuring range up to 4.0 OD.
  • Built-In Plate Conditioning: Linear shaking at three speeds and incubation up to 45°C prepare samples inside the instrument.

For automated plate washing before reading, pair the ELISA Microplate Reader with Monochromator with our ELISA Microplate Washer.

Product Features

Optics

  • Grating monochromator, 200-1000 nm in 1 nm increments
  • Xenon flash lamp light source
  • Wavelength accuracy 2 nm, repeatability 0.2 nm, bandwidth below 2.5 nm
  • Double-beam path with two silicon photodetectors

Plate Handling

  • Accepts 96-well and 384-well microplates
  • Linear shaking with three speed settings
  • Incubation from RT+4°C to 45°C, ±0.5°C at 37°C

Operation and Data

  • 10-inch touch screen for stand-alone use
  • 16 GB storage for more than 20,000 data files
  • 1 USB-B, 2 USB-A and 1 network port

HT Model

  • Additional cuvette slot for single samples
  • Cuvette reading from 200 to 1000 nm
  • Cuvette incubation

Applications

undefined

  • ELISA and other enzyme immunoassays
  • Protein quantification (BCA, Bradford, Lowry, UV 280 nm)
  • Nucleic acid quantification at 260/280 nm
  • Enzyme kinetics and activity assays
  • Cell viability and proliferation assays (MTT, CCK-8)
  • Wavelength scanning of unknown samples

Standard Accessories Included

  • ELISA microplate reader main unit (standard or HT model)
  • Power adapter (DC 24 V)

Optional Accessories

  • PC software
  • u-Nano ultra-micro plate (2-4 µL, 1-16 samples)
  • ABS optical validation board

Problems the ELISA Microplate Reader with Monochromator Solves

Labs that rely on filter-based readers often meet the issues below. The ELISA Microplate Reader with Monochromator addresses each one.

  • Filter readers only cover a few fixed wavelengths: The monochromator selects any wavelength from 200 to 1000 nm in 1 nm steps.
  • Slow reading delays high-throughput work: Fast mode reads a full 96-well plate in under 8 seconds.
  • Separate shaker and incubator take up bench space: Shaking at three speeds and incubation up to 45°C are built in.
  • Single samples waste a whole plate: The HT model adds a cuvette slot for single-sample readings.
  • Results lost without a PC: 16 GB internal storage holds more than 20,000 data files.

Frequently Bought Products

"Master Science - Leading Provider of Laboratory Equipment & Analytical Instruments"

"Explore Master Science, your trusted provider of high-quality laboratory equipment and innovative solutions. Discover our extensive range of analytical instruments and exceptional customer support, all dedicated to empowering scientific discovery across industries. Join us in advancing research and setting new standards globally."

All categories