The Master Science Dissolution Sampling System automates the sampling side of a dissolution test. Precision syringe pumps with 26 mL syringes draw, filter and dispense each sample, then replace the withdrawn medium with an equal volume, so the operator does not have to pull samples by hand at every time point.
Two versions are offered: Version A with 8 sampling channels and Version B with 12 channels. Both handle up to 16 sampling times per run, single volumes from 1 to 15 mL (expandable to 30 mL) and intervals from 1 minute up to 999 h 59 min. The Dissolution Sampling System connects to most dissolution testers and supports wireless online operation.
Technical Specifications
Values below are taken from the manufacturer specification sheet. Version A = 8 channels, Version B = 12 channels.
- Brand: Master Science
- Model Number: MSDISS-Y8SWISS,MSDISS-Y12SWISS
- SKU: MSDISS-Y8SWISS,MSDISS-Y12SWISS
- Sampling Channels: Version A: 8; Version B: 12
- Sampling Times: 16 times
- Sampling Modes: Precision, speed
- Sampling Accuracy: RSD <0.5%
- Sampling Interval: 1 min to 999 h 59 min
- Single Sampling Volume: 1-15 mL (expandable up to 30 mL)
- Sampling Consistency: Channel-to-channel RSD ≤1%
- Sampling Repeatability: RSD ≤0.5%
- Syringe: 26 mL, 0.5% accuracy
- Test Tube Collection Volume: 15 mL
- Dispensing Function: Available
- Liquid Replenishment: Equal-volume replenishment
- Initial Filtrate Volume: 0-10 mL
- Initial Filtration: 10 μm columnar filter tips
- Inline Filter: φ25 mm Luer-lock, cellulose membrane, 0.45 μm or 0.8 μm pore size
- Communication: Wireless network
- Privilege Management: 3 levels, 7 users
- Audit Trail: 128 entries × 366 days
- Login Method: Username + password, fingerprint
- Online Printing: Supported
Key Benefits
- Less manual handling: Samples are drawn, filtered and collected automatically at each programmed time point.
- Consistent volumes: Syringe pump drive gives repeatability of RSD ≤0.5% and channel-to-channel RSD ≤1%.
- Clean filtrate: Initial filtrate can be sent to waste before the retained portion is collected.
- Correct medium volume: Equal-volume replenishment returns fresh medium after each draw.
- Controlled access: Fingerprint or password login, three permission levels and an audit trail.
Pair the Dissolution Sampling System with an 8-vessel dissolution tester for a fully automated test setup.
Product Features
Sampling and Filtration
- Precision syringe pumps for filtration, sampling and medium replenishment
- Pre-filtration and terminal filtration; filters can be rinsed by circulation and are easy to replace
- Pump speed below 25 mL/min, with sampling and filtration usually finished within 30 s
- Precision and speed sampling modes
Tubing and Collection
- Corrosion-resistant, high-pressure-resistant tubing
- 10 mL sample tubes with sealing caps supplied
- Optional collection into 2 mL or 10 mL sealed vials, or directly into ampoules
- Sampling needle with septum-piercing and vial-ejection mechanism and built-in PTFE tubing
Control and Data
- Wireless online operation
- Fingerprint and password login
- 3-level, 7-user privilege management with audit trail
- Online printing
Applications
The Dissolution Sampling System is used wherever dissolution samples must be collected on schedule with minimal operator time.
- Automated sampling for tablet and capsule dissolution tests
- Dissolution profile studies with many time points
- QC release testing in pharmaceutical labs
- Formulation development and comparison studies
- Collecting filtered samples for later HPLC or UV analysis
Standard Accessories Included
- 10 mL sample tubes with sealing caps
Optional Accessories
- 2 mL sample vials with sealing caps
- 10 mL sample vials with sealing caps
Common Laboratory Problems and How This Instrument Helps
Common sampling problems in dissolution testing and how the Dissolution Sampling System helps:
- Missed time points: Programmed intervals from 1 min to 999 h 59 min run without operator attention.
- Volume variation between vessels: Syringe pump sampling keeps channel-to-channel RSD ≤1%.
- Particles in samples: Initial and inline filtration remove undissolved material before collection.
- Medium volume loss: Equal-volume replenishment restores the vessel volume after each draw.
- Unclear records: Audit trail and user login show who ran each test.