The Master Science Compact Stability Chamber brings temperature and humidity control into a smaller footprint, with sizes from 70 to 250 litres. It suits labs that run stability or storage studies on a modest number of samples and do not need a walk-in or large cabinet.
Without humidification the chamber covers 5 to 65°C; with humidity control it works from 10 to 60°C and 45 to 95% RH. A PT100 sensor and PID controller handle temperature, a capacitive humidity sensor with anti-condensation design handles RH, and a 30-segment program allows step and loop profiles. Double doors with a glass inner door let you look at samples without disturbing the climate inside.
Technical Specifications
Specifications of the Master Science Compact Stability Chamber range:
- Brand: Master Science
- Model Number: MSICB-H70SWISS,MSICB-H150SWISS,MSICB-H250SWISS
- SKU: MSICB-H70SWISS,MSICB-H150SWISS,MSICB-H250SWISS
- Brand: Master Science
- Model: MSICB-H70SWISS, MSICB-H150SWISS, MSICB-H250SWISS
- SKU: MSICB-H70SWISS, MSICB-H150SWISS, MSICB-H250SWISS
- Capacity: 70 / 150 / 250 L
- Circulation: Forced convection
- Internal dimensions (W×D×H): 415 × 350 × 500 / 490 × 400 × 750 / 500 × 515 × 950 mm
- External dimensions (W×D×H): 571 × 661 × 1051 / 646 × 711 × 1301 / 656 × 811 × 1501 mm
- Temperature range: 5-65°C without humidification; 10-60°C with humidification
- Fluctuation: ±0.5°C (high temperature), ±1°C (low temperature)
- Resolution: 0.1°C
- Uniformity: ±1°C
- Temperature sensor: PT100
- Humidity range: 45-95% RH
- Humidity stability: ±5% RH
- Humidification: Internal
- Humidity sensor: High-precision, anti-condensation
- Controller: PID
- Display: Large LCD
- Timer: 0-99.99 h × 30 segments, with timed wait
- Chamber: Mirror stainless steel
- Exterior: Electrostatically coated cold-rolled steel
- Shelves (standard / max): 2/5, 2/9, 2/12
- Test port: Ø43 mm
- External socket: 1 universal socket
- Refrigerant: R134a (CFC free)
- Defrost: Automatic
- Safety: Over-temperature, over-humidity and water shortage alarms; mechanical independent temperature limiter
- Power supply: AC 220/110 V, 50/60 Hz
- Power consumption: 1800 / 2000 / 2200 W
- Net / gross weight: 69/92, 86/114, 100/139 kg
Key Benefits
- Small footprint, full control: The Master Science Compact Stability Chamber manages both temperature and humidity in 70 to 250 L.
- Check samples without upsetting them: A glass inner door keeps conditions stable while you look.
- Program long studies: 30 segments with loops and timed waits.
- Double safety: Electronic alarms plus an independent mechanical limiter.
For larger loads, see our temperature and humidity chamber 173-516 L, a bigger option than the Master Science Compact Stability Chamber.
Product Features
Climate control
- PT100 sensor with PID control
- Capacitive humidity sensor, anti-condensation
- Internal fine-particle humidifier with low water use
- Automatic defrost for long runs
Programming and display
- Large LCD with multiple values at once
- 30-segment program with loops and step running
- Loop self-diagnosis and sensor fault alarms
Construction and safety
- Mirror stainless steel chamber
- Double door: glass inner door, magnetic outer seal
- Mechanical independent temperature limiter
- Water shortage alarm
Applications
The Master Science Compact Stability Chamber is used for:
- Pharmaceutical stability studies
- Food and cosmetic shelf-life testing
- Electronic component humidity testing
- Material and packaging ageing
- Seed and biological sample storage under set humidity
Standard Accessories Included
- Stability chamber
- Shelves ×2
Optional Accessories
- Spare shelves
- RS485 port
- Built-in printer
- USB data storage
Testing Problems the Master Science Compact Stability Chamber Solves
Small labs often lack a dedicated, controllable climate for stability work. The Master Science Compact Stability Chamber helps with:
- No controlled humidity: Built-in humidification holds 45-95% RH.
- Conditions disturbed by checks: The glass inner door keeps the climate stable.
- Running out of water unnoticed: A water shortage alarm warns in time.
- Controller failure risk: An independent mechanical limiter adds protection.