The Master Science 6 L Cassette Autoclave is a fast steam sterilizer that processes instruments inside a removable cassette instead of a large chamber. An unwrapped cycle takes about 9 minutes from start to finish, which makes it useful for departments that share equipment and for urgent instrument turnaround.
It sterilizes both solid instruments and instruments with cavities. Operation is shown on the display, a cycle can be interrupted safely at any time, and a self-check system stops the Master Science 6 L Cassette Autoclave and displays a fault code if a problem occurs.
Technical Specifications
Technical data of the Master Science 6 L Cassette Autoclave:
- Brand: Master Science
- Model Number: MSSTC-6000SWISS
- SKU: MSSTC-6000SWISS
- Brand: Master Science
- Model: MSSTC-6000SWISS
- SKU: MSSTC-6000SWISS
- Sterilization Volume: About 6.0 L
- Cycle Time: About 9 minutes (unwrapped)
- Operating Temperature Range: 115 to 135°C
- Maximum Operating Temperature: 138°C
- Operating Pressure Range: 42 to 212 kPa
- Maximum Operating Pressure: 242 kPa
- Safety Valve Setting: 0.25 MPa
- Display Accuracy: 0.1°C
- Water Tank Volume: 3.4 L
- Water Type: Ultra-pure, deionized, distilled or purified laboratory water
- Steam Generator Power: 1.2 kVA ±5%
- Input Power: ≤ 1.3 kVA
- Power Supply: AC 220 V ±22 V, 50 Hz ±1 Hz
- Run Mode: Intermittent, up to 6 cycles per hour
- Equipment Size: 580 × 460 × 190 mm
- Chamber Size: 480 × 180 × 78 mm
- Cassette Size (outside): 570 × 210 × 80 mm
Key Benefits
- Very short cycle: Unwrapped instruments are sterilized in about 9 minutes.
- Handles hollow instruments: Suitable for cavity-containing as well as solid instruments.
- Safe interruption: A running programme can be stopped safely at any point.
- Clear diagnostics: Self-detection halts the unit and shows a fault code on screen.
For wrapped loads and larger batches, see our Class B benchtop autoclave.
Product Features
Operation
- On-screen display of system operation
- Programme can be interrupted safely at any time
- Up to 6 cycles per hour
Sterilization
- Removable sterilization cassette
- Non-wrapped sterilization in about 9 minutes
- Operating range 115 to 135°C
Safety
- Self-detection system with automatic stop
- Fault code display
- Safety valve set at 0.25 MPa
Applications
The Master Science 6 L Cassette Autoclave is suited to:
- Dental clinics needing quick handpiece and instrument turnaround
- Emergency and outpatient departments
- Ophthalmic and minor surgery units
- Shared instrument sets across departments
- Veterinary practices
Standard Accessories Included
- Cassette autoclave main unit
- Sterilization cassette
Problems the Master Science 6 L Cassette Autoclave Solves
Large autoclaves are slow when only a few instruments are needed urgently. The Master Science 6 L Cassette Autoclave helps with:
- Long waits for critical instruments: A 9-minute unwrapped cycle returns instruments quickly.
- Hard-to-reach cavities: The process is designed for instruments with lumens and cavities.
- Unclear errors: Fault codes on screen help identify the problem.
- Bench space: A low 190 mm profile fits under cabinets and on crowded counters.